{"id":5072,"date":"2026-11-24T23:50:05","date_gmt":"2026-11-24T15:50:05","guid":{"rendered":"https:\/\/ptfesuppliers.com\/?p=5072"},"modified":"2026-11-24T23:50:05","modified_gmt":"2026-11-24T15:50:05","slug":"ptfe-tubing-sizes-id-od-wall-thickness-and-tolerance-explained","status":"publish","type":"post","link":"https:\/\/ptfesuppliers.com\/ru\/ptfe-tubing-sizes-id-od-wall-thickness-and-tolerance-explained\/","title":{"rendered":"PTFE Tubing Sizes: ID, OD, Wall Thickness and Tolerance Explained"},"content":{"rendered":"<p><strong>Short answer:<\/strong> PTFE tubing is specified by four dimensions &mdash; inner diameter (ID), outer diameter (OD), wall thickness and length &mdash; with ID from roughly 0.5 to 200 mm and walls from 0.1 to 5 mm in commercial practice. Only two of the four are independent: OD = ID + 2 &times; wall, so you must specify exactly which two the manufacturer holds to tolerance.<\/p>\n<p>Sizing confusion is the number-one cause of tubing rework. A buyer specifies &#8220;6 mm tube&#8221; and receives ID 6, while the fitting expected OD 6. This reference gives the standard dimension conventions, realistic tolerances per size class, and how to write a tubing callout that cannot be misread.<\/p>\n<h2>The four dimensions and who controls what<\/h2>\n<table border=\"1\" cellpadding=\"6\">\n<tr>\n<th>Dimension<\/th>\n<th>Typical range<\/th>\n<th>Common tolerance<\/th>\n<th>Usually controlled by<\/th>\n<\/tr>\n<tr>\n<td>ID<\/td>\n<td>0.5&ndash;200 mm<\/td>\n<td>&plusmn;0.05&ndash;0.2 mm (small IDs tighter)<\/td>\n<td>Extrusion die &mdash; the primary process dimension<\/td>\n<\/tr>\n<tr>\n<td>Wall<\/td>\n<td>0.1&ndash;5 mm<\/td>\n<td>&plusmn;10&ndash;20% commercial; tighter by agreement<\/td>\n<td>Mandrel\/tooling and draw-down ratio<\/td>\n<\/tr>\n<tr>\n<td>OD<\/td>\n<td>derived<\/td>\n<td>&plusmn;0.1&ndash;0.3 mm<\/td>\n<td>Follows from ID + wall; specify only if fittings require it<\/td>\n<\/tr>\n<tr>\n<td>Length<\/td>\n<td>coils to ~50 m; cut lengths<\/td>\n<td>as agreed<\/td>\n<td>Packaging and post-cut accuracy<\/td>\n<\/tr>\n<\/table>\n<h2>Tolerance classes: what is realistic at each size<\/h2>\n<p>Paste-extruded small-bore tube (under ~10 mm ID) holds the tightest ID tolerances &mdash; &plusmn;0.05 mm is routine and &plusmn;0.02 mm achievable with die selection and screening. Large-bore ram-extruded tube (50&ndash;200 mm) typically carries percentage tolerances because the material&#8217;s post-extrusion relaxation dominates. Beware quotations promising metal-class tolerances on large bore &mdash; they are either unmeasured or unshipped. Eccentricity matters as much as nominal wall: a tube specified &#8220;0.5 mm wall&#8221; with 30% eccentricity has a 0.35 mm minimum wall, and that minimum is what bursts or collapses. Ask how eccentricity is measured and reported.<\/p>\n<h2>Writing an unambiguous tubing callout<\/h2>\n<p>Specify two dimensions with tolerance and state which is functional: for fittings, OD and wall (fittings grip outside); for flow calculations, ID and wall. A correct callout reads: <em>PTFE tube, ID 6.0 &plusmn;0.1 mm, wall 1.0 &plusmn;0.15 mm (min 0.85), length per coil 20 m, virgin PTFE<\/em>. Adding &#8220;min wall&#8221; protects you from average-based compliance. For high-purity or electrical uses, append the property that matters: dielectric strength (typically &ge;10 kV\/mm on thin wall) or extractables documentation for semiconductor lines.<\/p>\n<h2>Size programs and tooling<\/h2>\n<p>Standard programs cover common ID steps; anything off-standard requires a die. Tooling charges are usually modest and sometimes waived against volume &mdash; but the question to ask is whether the die is the supplier&#8217;s standard or newly cut, because newly cut tooling means first-article verification matters even more. Chunhuan extrudes <a href=\"https:\/\/ptfesuppliers.com\/product-category\/ptfe-products\/ptfe-tube\/\">PTFE tube from 0.5 to 200 mm ID<\/a> in-house with lot-level dimensional reports; supply your callout in the format above and the quote will state exactly which tolerances are held and how they are measured.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3>What sizes does PTFE tubing come in?<\/h3>\n<p>Commercial PTFE tubing covers roughly 0.5-200 mm ID with 0.1-5 mm walls. Only two dimensions are independent since OD = ID + 2\u00d7wall.<\/p>\n<h3>What tolerance can PTFE tube hold?<\/h3>\n<p>Small-bore paste-extruded tube holds \u00b10.05 mm ID routinely; large-bore ram-extruded tube carries percentage tolerances. Specify minimum wall, not just nominal.<\/p>\n<h3>Should I specify ID or OD for PTFE tube?<\/h3>\n<p>Specify the dimension your application grips or flows through, plus wall, and state which is functional. For fittings use OD + wall; for flow use ID + wall.<\/p>\n<h3>What is eccentricity in tubing?<\/h3>\n<p>Wall thickness variation around the circumference. A 0.5 mm wall tube with 30% eccentricity has only 0.35 mm minimum wall \u2014 the value that determines burst pressure.<\/p>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What sizes does PTFE tubing come in?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Commercial PTFE tubing covers roughly 0.5-200 mm ID with 0.1-5 mm walls. Only two dimensions are independent since OD = ID + 2\u00d7wall.\"}}, {\"@type\": \"Question\", \"name\": \"What tolerance can PTFE tube hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Small-bore paste-extruded tube holds \u00b10.05 mm ID routinely; large-bore ram-extruded tube carries percentage tolerances. Specify minimum wall, not just nominal.\"}}, {\"@type\": \"Question\", \"name\": \"Should I specify ID or OD for PTFE tube?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Specify the dimension your application grips or flows through, plus wall, and state which is functional. For fittings use OD + wall; for flow use ID + wall.\"}}, {\"@type\": \"Question\", \"name\": \"What is eccentricity in tubing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Wall thickness variation around the circumference. A 0.5 mm wall tube with 30% eccentricity has only 0.35 mm minimum wall \u2014 the value that determines burst pressure.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A practical guide to PTFE tubing sizes, covering specification details, supplier evaluation and questions to resolve before ordering.<\/p>","protected":false},"author":1,"featured_media":5073,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[212,216,217],"tags":[],"class_list":["post-5072","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-area","category-general-industrial","category-ptfe-tubes-rods-sheets"],"_links":{"self":[{"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/posts\/5072","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/comments?post=5072"}],"version-history":[{"count":1,"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/posts\/5072\/revisions"}],"predecessor-version":[{"id":5594,"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/posts\/5072\/revisions\/5594"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/media\/5073"}],"wp:attachment":[{"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/media?parent=5072"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/categories?post=5072"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ptfesuppliers.com\/ru\/wp-json\/wp\/v2\/tags?post=5072"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}