Short answer: For PTFE tube, engineering buyers should confirm four tolerance groups before ordering: OD and ID (usually ±0.05–0.1 mm on precision grades), wall thickness concentricity (the hidden variable that affects pressure rating), length (±1 mm is standard; tighter costs more), and — for tubing destined for fittings — ovality. PTFE’s thermal expansion means every tolerance is only meaningful at a stated temperature.
Tube tolerances are where PTFE differs most from metal sourcing. The material is dimensionally “soft” in every sense: it moves with temperature, deforms under handling, and can relax after cutting.
The Four Tolerance Groups
- OD/ID: standard commercial tubing runs wider bands; precision tube holds ±0.05 mm. State which positions are fitting-sealing surfaces — those need the tight band, the rest doesn’t.
- Concentricity/wall: the underrated one. A tube at nominal wall but off-center has a thin side that governs burst pressure. For pressure duties, ask for minimum wall, not nominal.
- Length: ±1 mm on cut lengths is routine. Autoclave or fixture-critical lengths justify ±0.2 mm at modest premium.
- Ovality: compression fittings seal on round tube. Shipping coils flattened tube; specify straight or supported packaging for fitting-duty tube.
Temperature: The Fine Print That Isn’t Fine
| Factor | Practical effect |
|---|---|
| Thermal expansion (~10× steel) | A tube at ±0.05 mm at 20 °C is out of band near 60 °C |
| Post-cut relaxation | Cut ends can deform; squareness needs bore support |
Always ask at what temperature the supplier’s tolerance applies, and measure incoming parts at controlled temperature if you’ll verify against it.
RFQ Wording That Works
“PTFE tube, OD 12.7 mm +0.05/−0.05, ID 9.5 mm ±0.1, minimum wall 1.4 mm, cut length 500 ±0.5 mm, tolerances valid at 23 °C, straight packaging.” One sentence; zero assumption gaps. Chunhuan supplies precision PTFE tubing to stated tolerances with temperature-referenced measurement records.
Frequently Asked Questions
What tolerances can precision PTFE tubing hold?
OD/ID at ±0.05 mm is achievable on precision grades; commercial tubing runs wider. Cut lengths hold ±1 mm standard, ±0.2 mm at premium.
Why is wall concentricity important for PTFE tube?
An off-center wall means one thin side governs burst pressure. For pressure duties, specify minimum wall rather than nominal.
At what temperature are PTFE tube tolerances valid?
Whatever the supplier states — typically 23 °C. PTFE’s thermal expansion is roughly 10× steel, so tolerances drift with temperature.
How should tube for compression fittings be specified?
Tight OD tolerance plus ovality control and straight/supported packaging — fittings seal on round, undistorted tube.