Short answer: A PTFE lined pipe RFQ needs six things: nominal size and pressure class, face standard and drilling (ANSI/DIN/JIS), lining thickness, end-to-end and face-to-face lengths, media with temperature range, and any fittings (elbows, tees, spacers). Missing any one of these usually means the quote comes back with assumptions you did not agree to.

Lined pipe is a system purchase, not a commodity one. Unlike bare pipe, dimensions are driven by the lining process, so two “identical” DN80 elbows from different makers may not share a flange-to-face dimension — which matters enormously when you are matching an existing installed line.

The Six RFQ Fields, Explained

  1. Size and pressure class — DN/NPS and the flange rating. Lined pipe commonly serves up to 10–16 bar depending on size and temperature.
  2. Face standard — ANSI B16.5, DIN 2576/2632, or JIS. State it explicitly; mixed-standard sites are common and this is the #1 cause of mismatched spools.
  3. Lining thickness — typical is 2.5–4 mm for pipe; specify if your corrosion engineer sized something specific. Ask whether thickness is nominal or minimum.
  4. Lengths — face-to-face per piece and total run. Lined pipe usually comes in fixed lengths (1.5 m, 3 m); custom spools need each length listed line by line.
  5. Media and temperature — including excursions. Permeation behavior and liner grade (PTFE vs PFA) depend on it.
  6. Fittings list — every elbow degree, tee, reducer and spacer, itemized. Fittings are priced and made individually.

Two Dimensions People Forget

Vacuum rating: if the line can see vacuum, state it. Lined pipe needs vacuum rings or reinforced liners above certain temperatures — discovering this after delivery is expensive.

Conductive vs static liner: if the media is a flammable liquid, anti-static lined pipe per applicable specifications may be mandatory. This changes the liner and the price; it cannot be retrofitted.

A Working RFQ Line-Item Format

ArticleSpec
Elbow 90°DN80, DIN PN10, lined PTFE 3 mm min, R=1.5D, face-to-face 200 mm
StraightDN80 × 3000 mm, lined PTFE 3 mm min
Media30% HCl, 20–80 °C, no vacuum, no static requirement

Chunhuan produces PTFE/PFA lined pipe and fittings to customer face-to-face requirements with lot-traceable liner certificates; send the media data and we return a lining recommendation with the quote.

Frequently Asked Questions

What dimensions matter most in a PTFE lined pipe RFQ?

Flange face standard (ANSI/DIN/JIS), face-to-face lengths per piece, and lining thickness. These three cause nearly all mismatches with existing installations.

Do PTFE lined pipes come in standard lengths?

Commonly 1.5 m and 3 m; custom spools are made to your listed face-to-face lengths, so itemize every piece in the RFQ.

What lining thickness is typical for PTFE lined pipe?

Usually 2.5–4 mm. Specify whether you need nominal or minimum-guaranteed thickness — the difference affects corrosion life.

When does lined pipe need vacuum rating or anti-static liner?

Vacuum service above the liner’s unsupported rating needs rings or reinforced liners; flammable media typically requires anti-static liner. Both must be stated at RFQ stage.